<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-28 19-31-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 6.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 14 kHz 15929 11,6580
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,0 dBr 4,54 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 14 kHz MIN: 9 kHz % above 76 kHz: 11,6580 Acquired: 2025/03/28 19.30.12 Total samples: 15929 Equivalent time: 0:13:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 5,7 dBr MIN: -1,0 dBr AVE: 4,54 dBr % above 12,2 dBr: 0,0 Last value: 0,8 dBr (2025/03/28 19.30.11) 19.16 19.18 19.20 19.22 19.24 19.26 19.28 19.30 0 2 4 6 Pm [dBr]